Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

This article provides information to successfully submit a project application and documents for electronic plan review to a back office Permitting agency, Plan Review Consulting firm or AEC Design review firm. 


Prior to uploading your plan review documents, select the 'DOCUMENT SUBMITTAL RECOMMENDATIONS' link and carefully review the requirements.

...

Below is a list of commonly known issues:



Documents must not exceed 400 MB

Issue

Description
Result
Solution
File Size

Is Active

Is Configurable

Configurations

Default Behavior

Default Result

Solution

ACCESSIBLE

Y

N

N/A

Checks if the file is invalid (such as a PDF Portfolio), corrupt, or password protected.

REJECTION

Check if PDF can be opened by Adobe Reader and confirm it is not a PDF Portfolio.

If the PDF cannot be opened, create a new PDF from the source program. Remove password protection, if applicable.

FILENAME

Y

Y

Filename Special Characters

Checks if filename contains: !*\();, :@&=+$, , (comma)/?%#[], " , <>, | characters. Characters cannot be edited.

REJECTION

Remove these characters from the filename and re-upload the file.

SIZE

Y

Y

Minimum/Maximum PDF size in bytes

Documents must not exceed 400 MB (419430400 bytes). Recommended maximum size is 2 GB.

REJECTION

Return to the source document and create PDF files that are below the file size limitation or break up PDF into smaller files.

Follow the instructions in

the

the DOCUMENT SUBMITTAL RECOMMENDATIONS

as shown abovePDF Version

.

Paper SizeChecks for paper sizes smaller than 8.5" x 11" or larger than 36" x 48"and will trigger a warning if detected.Warning

None required.

These suggestions are in place because most printers cannot print wider than 36 inches.

PAGE COUNT

Y

Y

Maximum page count

Checks the PDF page count based on the configured maximum page count. The default is set to 1200 pages.

REJECTION

Split large files into smaller subsets and submit files separately or the Agency can choose to increase the maximum page count.

TEXT CONTENT

N

Y

N/A

Checks whether PDF text and fonts are present and legible.

N/A

Properly embed or substitute missing font. Using true type fonts is recommended.

VERSION

Y

N

N/A

Checks PDF version.

If PDF

version

version older than 1.

3 is

4 is detected, the file will be rejected. (Version 1.

3 Update

4 was released prior to 2001.)

REJECTION


Warning

None required but it is recommended to update the PDF to a newer version.

Password protection

The inspector checks for password security that prevent opening the PDF

If the PDF cannot be opened, the file will be rejected.

REJECTIONRemove the password protection to allow PDF access.Page Access

PAGE ACCESS

Y

Y

N/A

The inspector tries to read each page in the document.

If a page is not readable, the file will be rejected.


REJECTION

Adobe Reader may report these pages as damaged or in need of repair.

Recreate the PDF from the source document using Adobe Pro or Nitro Pro.

Annotations/SHX Text

ANNOTATION

Y

Y

N/A

Checks for annotations that appear in the pdf Reader ‘Comment’ panel,

such

 such as SHX Text generated by AutoCAD.

 

Warning

None required.

Note that SHX text annotations will be removed from pdf 'Comment' panel when printing deliverable files so they do not interfere with review comments. (No other annotations will be removed.)

Filename Special CharactersChecks if filename contains any of the following characters: 

!  *  –  \   ;   :   @   &   =   +   $   ,   /   ?   %   #   [   ] '  “   <   >   | 

REJECTIONRemove these characters from the filename and re-upload file.Page OrientationChecks if document has mixed page orientations

METADATA

Y

Y

N/A

Check hidden content and unexpected metadata like embedded Flash, other PDFs, etc.

Warning

Remove hidden content by following the instructions listed in the EPR Wiki document “How To Remove Metadata from PDF”.

SIGNATURE

Y

Y

N/A

Checks for the presence of a digital signature in the PDF.

Warning

Validates that the signature exists but cannot confirm source authenticity.

ATTACHMENT

Y

Y

N/A

Checks if any attachments exist in the PDF.

REJECTION

Recreate the PDF without any attachments or reprint PDF as new to remove attachments.

RESOLUTION

Y

Y

Minimum/Maximum pixel count

Checks pages for low resolution (in pixels) based on page dimensions.

Warning

Create a new PDF from the source.

ROTATION

Y

Y

N/A

Checks if a document has mixed page orientations based on the first page orientation. Scout does not look at page content so, it cannot determine if pages are upside-down, for example.

Warning

None required.

Manually checking that pages are not upside-down or sideways is recommended.

 PDF PortfoliosPortfolio PDFs or PDFs with attachments will be rejected as they are a serious security issue. (see PDF Portfolios)REJECTIONA PDF Portfolio contains multiple files assembled into an integrated PDF unit. The files in a PDF Portfolio can be in a wide range of file types created in different applications.
For example, a PDF Portfolio can include scrips, macros, text documents, e-mail messages, spreadsheets, CAD drawings, and PowerPoint presentations

Page rotation can now be corrected within EPR.


SUBMITTING CORRECTED PLANS AND REVISIONS

...